Übersetzung für "Internal interrupt" in Deutsch

The microprocessor Intel 8051 has the possibility of carrying out a so-called internal time-interrupt program.
Der Mikroprozessor INTEL 8051 bietet die Möglichkeit, ein sogenanntes internes Timer-Interrupt-Programm abzuarbeiten.
EuroPat v2

Finally I decided to use the internal interrupt driver of the OS.
Letztlich habe ich mich aber entschlossen, den internen Interrupt-Treiber des Betriebssystems zu verwenden.
ParaCrawl v7.1

In addition to the test status register TSR, the test information register TIR and the test control register TCR, the following elements are all coupled to the internal bidirectional bus IBUS: an internal memory IMEM, a port PORT having a plurality of input and output lines and a processor core PC, wherein the processor core is additionally connected to the internal processor reset line PRI, the internal processor interrupt line PII, and the internal processor clock line CER.
Neben dem Teststatusregister TSR, dem Testinforegister TIR und dem Testcontrollregister TCR sind zudem ein interner Speicher IMEM, ein mehrere Ein- und Ausgabeleitungen aufweisender Port PORT und ein Prozessorkern PC, der zusätzlich an die interne Prozessorresetleitung PRI, die interne Prozessorinterruptleitung PII, die Testlogikresetleitung TLR und eine Zellenleseleitung CER angeschlossen ist, mit dem internen bidirektionalen Bus IBUS gekoppelt.
EuroPat v2

An internal interrupt request can be sent to the central unit through the interrupt request flags IR1, IR2, IR3 whenever the particular register T1, T2, T3 causes a counter overflow or underflow, that is whenever counting proceeds past the maximum displayable number or, in downward counting, when counting passes below zero.
Über die Unterbrechungsanforderungs-Flags IR1, IR2, IR3 kann eine interne Unterbrechungsanforderung an die Zentraleinheit abgegeben werden, wenn das jeweilige Register T1, T2, T3 einen Zählerüberlauf bzw. -unterlauf verursacht, d. h. wenn über die größte darstellbare Zahl hinausgezählt oder beim Abwärtszählen unter Null gezählt wird.
EuroPat v2

The internal control which is also designed as a microcomputer, has the possibility of controlling the interface module via registers which can be addressed directly, or of interrogating states and thus initiating or affecting the following internal sequences: The interrupt-controlled access to status data (LL logic); the interrupt-controlled access to 64 kbit channels on the speech path side and the subscriber side; the exchange of data blocks between the interface module and the central controller; and the expansion of the logicl level of the data exchange in the message format with variable data length (HDLC procedure).
Die interne Steuerung, die auch als Mikrocomputer ausgeführt ist, hat die Möglichkeit, die Schnittstellenbaugruppe über direkt adressierbare Register zu steuern bzw. Zustände abzufragen und damit folgende interne Abläufe einzuleiten bzw. zu beeinflussen und zwar der interruptgesteuerte Zugriff auf Zustandsdaten (LL-Logik), der interruptgesteuerte Zugriff auf sprechwege- und teilnehmer-seitige 64-kbit-Kanäle, der Austausch von Informationspaketen zwischen der Schnittstellenbaugruppe und der zentralen Steuerung, sowie die Erweiterung der logischen Ebene des Datenaustausches im Nachrichtenformat mit variabler Datenlänge (HDLC-Prozedur).
EuroPat v2

Outputs of the decoder DEC2 are connected to an internal processor reset line PRI, an internal processor interrupt line PII and a test logic reset line TLR.
Die Ausgänge des Decoders DEC2 sind an eine interne Prozessorresetleitung PRI, eine interne Prozessorinterruptleitung PII und eine Testlogikresetleitung TLR angeschlossen.
EuroPat v2

If the logic combination element is configured as an OR gate, the internal interrupt signal of the microprocessor is activated when the respectively interrogated condition is present at the at least one of the state input signals.
Wenn dieses Verknüpfungselement als ODER-Verknüpfung ausgeführt ist, wird das mikroprozessorinterne Interruptsignal dann aktiviert, wenn an mindestens einem der Zustandssignaleingänge die jeweils abgefragte Bedingung vorliegt.
EuroPat v2

If the logic combination element is an AND gate, the internal interrupt signal of the microprocessor is activated when a predetermined combination of state signal states is present.
Wenn dieses Verknüpfungselement eine UND-Verknüpfung ist, wird das mikroprozessorinterne Interruptsignal dann aktiviert, wenn eine vorbestimmte Kombination von Zustandssignalzuständen vorliegt.
EuroPat v2

If the switch 8 is connected to the OR gate 6, the internal interrupt signal IR of the microprocessor is generated when the state sought has appeared at at least one of the inputs 1, 2, . . . .
Wenn der Schalter 8 mit dem ODER-Gatter 6 verbunden ist, wird das mikroprozessorinterne Interruptsignal IR dann erzeugt, wenn an mindestens einem der Eingänge 1, 2,... der nachgesuchte Zustand eingetreten ist.
EuroPat v2

Depending on the desired configuration scope, soft CPUs such as the MicroBlaze™ have a configurable three- to five-stage pipeline, internal cache, an interrupt, a hardware-based multiplier, and optionally a hardware-based divider, a floating-point unit and special shift register units as well as multiple different buses that are provided for connecting to a wide range of peripherals and memory in a programmable logic element.
Je nach gewünschtem Konfigurationsumfang haben Soft-CPUs wie der MicroBlaze™ eine konfigurierbare drei- bis fünfstufige Pipeline, internen Cache, einen Interrupt, einen hardwarebasierten Multiplizierer und optional eine hardwarebasierende Divisionseinheit, eine Fließkommaeinheit und spezielle Schieberegistereinheiten, sowie mehrere unterschiedliche Busse, welche für den Anschluss von umfangreicher Peripherie und Speicher in einem programmierbarer Logikbaustein vorgesehen sind.
EuroPat v2

The required interrupt calls for triggering the interrupt routines are performed from an internal interrupt source of the PC system, wherein according to a preferred embodiment the timers of the PC system which cause the system clock calls, i.e., for example the timer 0, are used therefor.
Die notwendigen Interrupt-Anforderungen zum Auslösen der Interruptroutinen werden dabei von einer internen Interrupt-Quelle des PC-Systems durchgeführt, wobei gemäß einer vorteilhaften Ausführungsform hierzu die Zeitgeber des PC-Systems, die die Systemtaktaufrufe bewirken, d.h. z.B. der Timer 0, herangezogen werden könnte.
EuroPat v2

To ensure a reliable real time processing, according to the preferred embodiment of the invention, security measures against an undesired re-programming in particular of the internal interrupt source of the PC system are provided.
Um einen sicheren Echtzeitbetrieb ausführen zu können, sind gemäß einer bevorzugten Ausführungsform Sicherungsmaßnahmen gegen ungewünschte Umprogrammierungen, insbesondere der internen Interrupt-Quelle des PC-Systems, vorgesehen.
EuroPat v2

Preferably the ceramic component according to the invention is a spacer for catalyst use with variable wall thickness and interrupted internal chamfer. DETAILED DESCRIPTION
Bevorzugt ist das erfindungsgemäße keramische Bauteil ein Distanzring für den Katalysatoreinsatz mit variabler Wandstärke und gegebenenfalls unterbrochener Innenfase.
EuroPat v2

The ceramic component according to the invention is preferably a spacer ring for catalyst use with variable wall thickness and an interrupted internal chamfer.
Vorzugsweise handelt es sich beim erfindungsgemäßen keramischen Bauteil um einen Distanzring für den Katalysatoreinsatz mit variabler Wandstärke und gegebenenfalls unterbrochener Innenfase.
EuroPat v2

References to the pertaining interrupt routines are deposited in the interrupt descriptor table IDT of the real-time operating system under the location numbers of the internal interrupts d, e, f, g, of the operating system.
Unter den Platznummern der betriebssystemeigenen Interrupts d, e, f, g sind in der IDT des Echtzeitbetriebssystems Verweise auf die zugehörigen Interruptroutinen hinterlegt.
EuroPat v2

One of these internal interrupts of the operating system is identical to the first periodical event PA1 that is intended to initiate a handling of the second branch subsystem SUB2.
Einer dieser betriebssystemeigenen Interrupts ist mit dem ersten periodischen Anreiz PA1 identisch, der eine Abarbeitung des weiteren Schleusensubsystems SUB2 einleiten soll.
EuroPat v2

The EP transformer is switched off by means of an internal signal, by interruption of the control for the braking and release magnet valve.
Der EP-Wandler wird über ein internes Signal ausgeschaltet, durch Unterbrechen der Ansteuerung für die Brems- und Lösemagnetventile.
EuroPat v2